Connect IO-Link sensors without a data line
Traditionally every new measurement point means pulling cable, filling trays, terminals in the cabinet and a configured PLC input. With AION LIO the IO-Link sensor stays where it is and sends its process data over LoRaWAN®.
Where cables get expensive
Long runs across halls, roofs or sites, full cable trays, fire compartments, hazardous areas or plants that can't stop: often the cable costs more than the sensor.
- 1. Sensor stays – The existing or new IO-Link sensor plugs straight into AION LIO.
- 2. Master reads – AION LIO acts as IO-Link master and reads process data and diagnostics.
- 3. Radio, not cable – Values travel over LoRaWAN® to the gateway – through walls and over distance.
- 0 m
- data line to the controller
- 1
- adapter per sensor
- km
- LoRaWAN® range
Two standards, one adapter
IO-Link
The vendor-independent standard for smart sensors (IEC 61131-9). Process values, parameters and diagnostics arrive digitally, described by an IODD – from thousands of sensors by many manufacturers.
LoRaWAN®
The open radio network for the industrial IoT: kilometre range, through walls and across sites, private or public networks, standardised forwarding to your application.
AION LIO is the IO-Link master that connects both: plug in the sensor, the IODD is parsed, readings go out over LoRaWAN®.
- No cable tray
No routing, no wall openings, no inspection for new data lines.
- No cabinet work
No extra terminals, couplers or input cards.
- Less downtime
Mounting at the sensor instead of work on running automation.
- Easy to relocate
Moving a measurement point means taking the adapter along.
IO-Link Wireless or IO-Link over LoRaWAN®?
IO-Link Wireless is a separate standard of the IO-Link Community for wireless communication inside a machine or cell. AION LIO instead uses wired IO-Link at the sensor and LoRaWAN® for the link to the application. They solve different tasks.
| IO-Link Wireless | AION LIO + LoRaWAN® | |
|---|---|---|
| Radio | 2.4 GHz, for the factory floor | Sub-GHz (868 MHz in the EU) |
| Range | Machine and cell level, typically a few metres | Hundreds of metres to kilometres |
| Timing | Near real-time, millisecond cycles | Periodic, minute or event based |
| Sensors | Dedicated IO-Link Wireless devices or bridges | Existing wired IO-Link sensors |
| Infrastructure | Wireless master at the machine, PLC integration | LoRaWAN® gateway and network server, no PLC needed |
| Typical use | Rotating parts, tool changers, robotics | Distributed points, tanks, legacy plants, outdoor sites |
Rule of thumb: if you need fast control data inside the machine, IO-Link Wireless fits. If you want distributed sensor values in your monitoring without cables or PLC changes, AION LIO with LoRaWAN® is the simpler solution.
Does AION LIO still need a cable?
Only the sensor supply (24 V DC). The data link to the controller or gateway is gone.
How far does LoRaWAN® reach?
Indoors typically several hundred metres, outdoors up to kilometres – depending on gateway position and environment.