Hard to reach
Basements, roofs, outdoor areas, distributed sites.
Plants grow and requirements change. With AION LIO a new measurement point is another adapter – not another cable run. Your monitoring grows with the plant.
The tank on the outdoor site, the pump in the basement, the unit at the far end of the hall: exactly where nobody passes regularly, data is usually missing.
Basements, roofs, outdoor areas, distributed sites.
Add points as needed instead of planning everything at once.
Level, pressure, flow and condition in the same network.
Open standards IO-Link and LoRaWAN® instead of island solutions.
Where are readings missing today – level, pressure, flow, vibration?
Pick a suitable IO-Link sensor from the broad vendor range.
Plug in AION LIO – the point appears in your platform.
The vendor-independent standard for smart sensors (IEC 61131-9). Process values, parameters and diagnostics arrive digitally, described by an IODD – from thousands of sensors by many manufacturers.
The open radio network for the industrial IoT: kilometre range, through walls and across sites, private or public networks, standardised forwarding to your application.
AION LIO is the IO-Link master that connects both: plug in the sensor, the IODD is parsed, readings go out over LoRaWAN®.
IO-Link Wireless is a separate standard of the IO-Link Community for wireless communication inside a machine or cell. AION LIO instead uses wired IO-Link at the sensor and LoRaWAN® for the link to the application. They solve different tasks.
| IO-Link Wireless | AION LIO + LoRaWAN® | |
|---|---|---|
| Radio | 2.4 GHz, for the factory floor | Sub-GHz (868 MHz in the EU) |
| Range | Machine and cell level, typically a few metres | Hundreds of metres to kilometres |
| Timing | Near real-time, millisecond cycles | Periodic, minute or event based |
| Sensors | Dedicated IO-Link Wireless devices or bridges | Existing wired IO-Link sensors |
| Infrastructure | Wireless master at the machine, PLC integration | LoRaWAN® gateway and network server, no PLC needed |
| Typical use | Rotating parts, tool changers, robotics | Distributed points, tanks, legacy plants, outdoor sites |
Rule of thumb: if you need fast control data inside the machine, IO-Link Wireless fits. If you want distributed sensor values in your monitoring without cables or PLC changes, AION LIO with LoRaWAN® is the simpler solution.
A LoRaWAN® gateway can serve many hundreds of devices with periodic readings – depending on interval and environment.
No. LoRaWAN® is meant for periodic monitoring. Fast control data remain the job of wired automation or IO-Link Wireless.